Oxy-Fuel Glass Kiln Ceramic Filter: Lines 1, 2, 4 | ZTW Tech
Search intent: case study / supplier evaluation|Every figure below is taken from a project ZTW Tech has built, commissioned or operated. Customer names follow the same anonymisation used in our Chinese-language case record. Where a number is a product rating rather than a measured stack value, it is labelled as such.
1. Project at a glance
| Item | Value |
|---|---|
| Owner | A glass manufacturer in Sichuan Province, China (name withheld under the site's standard anonymisation) |
| Industry | Oxy-fuel glass melting (container and daily-use glass) |
| Scope | Furnace lines 1, 2 and 4 |
| Technology | CeraCAT WK-POWFRAX ceramic fibre filter for hot dust removal, desulphurisation and defluorination, plus a medium-temperature SCR denitrification stage |
| Status | First ceramic integrated flue gas treatment application on an oxy-fuel glass melting furnace in China |
| Headline result | Flue duct cleaning interval extended from every 2 days to every 20-30 days |
2. Why oxy-fuel glass is a different duty
Oxy-fuel melting changes the flue gas in ways that matter. With pure oxygen as the oxidant there is no nitrogen dilution, so the exhaust stream leaves the furnace highly concentrated in CO2 and carries a heavy NOx load. The combustion reaction also produces a high water-vapour content, and the glass batch supplies fluoride. The combination is hot, wet, sticky, high in NOx and high in fluoride.
- High NOx. No nitrogen dilution means the NOx concentration is far above what an air-fired furnace of the same size produces.
- High fluorides. Fluoride is released from the glass batch itself, not from the fuel, so it cannot be avoided by changing fuel.
- Sticky, high-moisture flue gas. The gas condenses and forms a viscous film on cool surfaces.
- Molten carry-over. Glass droplets and entrained molten material travel with the gas and lodge in ductwork.
The practical consequence, and the reason this case is in our record, is that a conventional environmental train could not be made reliable on this duty. Both compliance and system availability were affected by the same root cause: gas that condenses and carries molten material. Our ceramic elements for sticky gas applications note sets out the mechanism in more detail.
3. The selected process route
Rather than forcing every duty into one vessel, this project splits it at the natural boundary. The ceramic fibre element handles the physical and acidic side of the duty; the SCR stage handles the catalytic NOx side.
| Unit | Duty | Reason for the split |
|---|---|---|
| CeraCAT WK-POWFRAX ceramic fibre filter | Hot dust removal, desulphurisation, defluorination | Ceramic fibre tolerates sticky, high-dust, high-fluoride gas far better than fabric media and does not blind |
| Sorbent and reductant injection | Ca(OH)2 for sulphur and acid capture, ammonia for SCR | Metred injection ahead of the filter keeps the surface working and limits reagent use |
| Medium-temperature SCR stage | NOx reduction | Keeps the denitrification reaction at the temperature where the catalyst performs, instead of trading efficiency for a single-vessel compromise |
| Back-blowing and ash handling | Element cleaning and by-product removal | Keeps pressure drop stable and turns the sorbent by-product back into a usable solid |
Each ceramic element is discussed in more detail in our Powfrax® 600-900°C ceramic fibre filter element and CeraCAT® ceramic catalytic filter element pages.
4. Reliability: the result that mattered most
For a continuous-process glass plant, an emission number that is met on the day of the test is worth less than a system that stays available. The before-and-after figure on duct cleaning is the clearest single indicator of that.
| Metric | Before the ceramic system | After the ceramic system |
|---|---|---|
| Flue duct cleaning interval | Every 2 days | Every 20 to 30 days |
| Cause of blockage | Molten glass carry-over condensing and lodging in the duct | Conditioned, filtered gas with far less entrained molten material |
| Effect on availability | Frequent manual intervention on a continuous line | Routine maintenance interval aligned to the plant shutdown cycle |
The emission outcome was also met, but the reliability gain is what converted a compliance project into an operating improvement.
5. What this case demonstrates for oxy-fuel projects
Oxy-fuel melting is expanding across the global glass industry because it cuts fuel use and CO2 per tonne of glass. The flue gas consequence is that the treatment train has to change too. Three findings from this project carry over directly:
- A high-moisture flue gas will condense on any cool surface. Dry conditioning ahead of the filter is not optional on this duty.
- Fluoride comes from the batch, so it is a permanent feature of glass flue gas regardless of fuel. It has to be designed in from the start.
- Molten carry-over is a ductwork problem before it is an emissions problem. Fixing the gas quality fixes the duct.
6. Frequently Asked Questions
Why is an oxy-fuel glass kiln a different problem from a regular one?
Pure oxygen combustion removes the nitrogen from the oxidant, so the flue gas leaves the furnace with very little nitrogen dilution. Concentrated CO2 carries a high NOx load, and the high water content produced by the reaction can condense in the ductwork. The glass batch itself supplies fluoride, so HF is high as well. The result is a gas that is simultaneously hot, sticky, wet, high in NOx and high in fluoride — a combination that conventional dry ESP plus baghouse plus SCR trains are not built for.
What process route was selected, and why was it not a single ceramic reactor?
For this duty the route is CeraCAT WK-POWFRAX ceramic fibre elements doing hot dust removal, desulphurisation and defluorination, combined with a medium-temperature SCR stage for denitrification. The split was deliberate: the ceramic fibre element tolerates the sticky, high-dust, high-fluorine gas, while the SCR stage handles the NOx at the temperature where the catalyst works. Splitting them kept both duties inside their optimal operating envelopes instead of forcing a compromise.
What was the most valuable operational result?
Reliability. Before the retrofit, the flue duct had to be cleaned every two days because molten glass carry-over kept blocking it. After the ceramic system was commissioned, the cleaning interval extended to every 20 to 30 days. For a glass plant running continuously, that change alone is worth more than most of the emission numbers.
Is this a first-of-a-kind installation?
Yes, in China it is the first project to apply ceramic integrated flue gas treatment technology to an oxy-fuel glass melting furnace. Oxy-fuel melting was itself still being adopted in China at that point, and the flue gas from it had no established treatment train that could be relied on.
How do I verify a case like this before committing to a supplier?
Ask for the measured stack concentrations before and after treatment with the operating conditions attached, and specifically ask what the duct cleaning interval was before and after. You can also request a free ceramic filter sample and test it against your own flue gas before deciding.
7. Related reading